CIOMP OpenIR
Prediction of lifetime by lumen degradation and color shift for LED lamps, in a non-accelerated reliability test over 20,000 h
J.Hao; H.L.Ke; L.Jing; Q.Sun; R.T.Sun
2019
发表期刊Applied Optics
ISSN1559-128X
卷号58期号:7页码:1855-1861
摘要Although the predicted lifetime of the classical 6000 h test given by Energy Star is taken as the normal lifetime of LED products in most research and applications, the aim of this study is to explore the error in lifetime prediction of LED lamps based on the 6000 h test. A non-accelerated aging test with 10 LED lamps is conducted for 20,000 h (from March 2016 to now) under room temperature, which is long enough for this kind of lamp reaching the real lifetime with the normalized luminous flux dropping to 70% naturally. At different aging periods, the correspondent lifetime of each sample is predicted by the lumen degradation, and the median lifetime tau(0.5) of 10 samples is obtained by applying the Weibull distribution. Result shows that the tau(0.5) of the real lifetime is 16,867 h in this work, and the aging time should be at least 9000 h to make the error in predicting the lifetime less than 3%. On the other hand, the Du'v' values of 0.006, 0.007, and 0.008 are taken as the three thresholds for predicting the lifetime by color shift. For the case of 0.008, the calculated shape parameter of 8.4 in Weibull distribution is similar with that of the real lifetime, which means the Du'v' of 0.008 for this kind of lamp gives the same failure mechanism as that of lumen degradation of 70%. (C) 2019 Optical Society of America
关键词online,design,Optics
DOI10.1364/ao.58.001855
URL查看原文
收录类别SCI
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/63339
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
J.Hao,H.L.Ke,L.Jing,et al. Prediction of lifetime by lumen degradation and color shift for LED lamps, in a non-accelerated reliability test over 20,000 h[J]. Applied Optics,2019,58(7):1855-1861.
APA J.Hao,H.L.Ke,L.Jing,Q.Sun,&R.T.Sun.(2019).Prediction of lifetime by lumen degradation and color shift for LED lamps, in a non-accelerated reliability test over 20,000 h.Applied Optics,58(7),1855-1861.
MLA J.Hao,et al."Prediction of lifetime by lumen degradation and color shift for LED lamps, in a non-accelerated reliability test over 20,000 h".Applied Optics 58.7(2019):1855-1861.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Prediction of lifeti(1269KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[J.Hao]的文章
[H.L.Ke]的文章
[L.Jing]的文章
百度学术
百度学术中相似的文章
[J.Hao]的文章
[H.L.Ke]的文章
[L.Jing]的文章
必应学术
必应学术中相似的文章
[J.Hao]的文章
[H.L.Ke]的文章
[L.Jing]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Prediction of lifetime by lumen degradation an.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。